Electrical insulating gloves are a lineman’s primary line of defense against high-voltage shock. Over time, physical wear, ozone cutting, corona damage, or chemical exposure can compromise their dielectric integrity.
Burlington Safety Laboratory provides comprehensive, ASTM-compliant testing services for electrical safety gloves across our state-of-the-art testing facilities in New Jersey and California. With a standard 2-week turnaround time (and expedited options available), we ensure your team stays safe, compliant, and equipped.

Why Choose Burlington Safety Lab for High Voltage Glove Testing?
- NAIL for PET Accredited: Certified independent laboratory testing since 1971.
- Full ASTM / OSHA Compliance: Tested strictly to ASTM D120 and F496 standards.
- Seamless Replacement Program: New product inventory ready to replace failed equipment immediately.
- Complete Traceability: Detailed test documentation, ink date stamping, and serialized record-keeping provided with every order.
Rubber Safety Glove Compliance & Testing Specifications
To remain compliant with OSHA 1910.137 and NFPA 70E, electrical insulating gloves must undergo dielectric laboratory retesting every 6 months.
Spec Feature | Standard Specification Details |
|---|---|
Applicable Standards | ASTM D120 (Manufacturing) & ASTM F496 (In-Service Care/Testing) |
Glove Classes Tested | Class 00 (500V) through Class 4 (36,000V) |
Required Test Frequency | Every 6 months (In-Service) / 12 months (Unissued/Stored) |
Accreditation | NAIL for PET (North American Independent Laboratories for Protective Equipment Testing) |
Turnaround Time | Standard 2-Week Turnaround (Expedited Services Available) |
Our 9-Step Dielectric Testing Process for Rubber Safety Gloves
Every pair of rubber insulating gloves submitted to Burlington Safety Laboratory passes through a rigorous 9-step quality assurance workflow:
Step 1: Preparatory Cleaning
Gloves are thoroughly washed using mild detergents in industrial washing equipment. This step removes dirt, grease, oils, and previous test stamps without degrading the natural rubber properties.
Step 2: Machine Drying
Following cleaning, gloves undergo controlled warm-air drying to prepare the material for accurate electrical evaluation.
Step 3: Dielectric High-Voltage Testing
Gloves are loaded into precision testing machines and submerged for dielectric breakdown and leakage current testing. In accordance with ASTM standards, proof voltage is applied based on the glove’s specific class rating (Class 00 to Class 4). Any glove exhibiting electrical breakdown or excess leakage current is automatically flagged.
Step 4: Re-Drying Process
After water bath dielectric testing, gloves pass through a second round of warm-air drying before moving to physical inspection.
Step 5: Air Testing & Visual Inspection
Considered the most critical stage of glove re-certification, gloves are inflated on pneumatic air testing stations. Our experienced technicians inspect every millimeter inside and out for hidden defects, including:
- Ozone cracking, UV damage, and corona cutting
- Cuts, nicks, snags, and scratches
- Chemical exposure, soft spots, and embedded debris
Step 6: Serialized Stamping
Gloves that pass both dielectric and visual inspections are stamped in durable ink with the proof test voltage, test date, and a unique tracking serial number.
Step 7: Individual Bag Packaging
Each certified pair is heat-sealed in an individual protective plastic bag to prevent contamination and mechanical damage during transit.
Step 8: Boxing & Labeling
Gloves are boxed and sealed with Burlington Safety tape. Box labels display the serial number, class rating, and retest dates for clear inventory tracking.
Step 9: Delivery or Pickup
Finished orders are shipped via UPS or made available for customer pickup at one of our regional facilities (Burlington, NJ; Pleasanton, CA; Westminster, CA).
Immediate Replacement for Failed Gloves
If a glove fails either dielectric voltage testing or physical air inspection, safety regulations prohibit it from returning to service.
Burlington Safety Laboratory maintains a complete inventory of new, freshly tested Class 00 through Class 4 rubber gloves from industry-leading manufacturers. We can instantly replace rejected items from stock so your crew suffers zero operational downtime.
Ready to Recertify Your Electrical Gloves?
Ensure your line workers stay protected and fully compliant with OSHA and ASTM guidelines.